For
all your radioactivity needs click below
Low cost g
& Positron
Radio-HPLC Detector
Low cost Radioactivity
g
& Positron TLC Scanner
Radio-GC Detector
Shielding Box 32 TLC Plates (Fuji etc)
Low cost single sample g
counter
WINDOWS software for above
Radiation Monitoring
(Hand,
Foot, Portal, Floor, Survey)
ROBO CLEAN-400
automated robotic scintillation vial cleaning system
BURNCLEAN Series I, II
& III radioisotope incinerators
WINDY 2000 Far-IR Animal
Drying System
Iatroscan MK-6 TLC-FID/FPD Analyzer / IATROBEADS
We now accept

| |
Area Radiation Monitor
 | LED
Digital Display
|
 | Low
and High Alarm Indicators
|
 | Programmable
Alarm Indicator
|
 | Built-In
Energy Compensated G-M
|
 | Optional
Remote
|
 | Detector
Fail Indicator
|
 | Battery
Backup
|
 | Data
Output/RS-232
|
 | Total
Counting Range from 1 mR/hr - 4 R/hr
|
|

|
|
INDICATED USE: Area monitoring
COMPATIBLE DETECTORS: Geiger-Mueller
RANGE: 1 mR/hr - 4 R/hr
DISPLAY: 4 digit LED display with 0.8"(2cm) character height
DISPLAY RANGE: 000.0 - 9999
DISPLAY UNITS: Can be made to display in microR/hr, mR/hr, R/hr,
microSv/h, mSv/h, Sv/h, cpm, cps, and others
LINEARITY: Reading within plus or minus 10% of true value with
detector connected
RESPONSE: Typically 3 seconds from 10% to 90% of final reading
STATUS: (green light) Indicates the instrument is
functioning properly
LOW ALARM: Indicated by a yellow light and slow beep (1 per
second) audible tone (can be set at any point from 0.0 - 9999)
HIGH ALARM: Indicated by a red light and fast beep (4 per second)
audible tone (can be set at any point from 0.0 - 9999)
NOTE:Audible indicators can be configured as a single beep if
desired.
DET FAIL: (red light and audible tone; greater than 68 Db at 2
feet) Indicates detector overload, no count from detector, or
instrument failure
LOW BAT: (yellow) Indicates less than 2 hours of battery
power remaining
CONNECTOR: Series "C" (others available )
CALIBRATION CONTROLS: Accessible from front of instrument (protective
cover provided )
HIGH VOLTAGE: Adjustable from 200 - 2500 volts
THRESHOLD: Adjustable from 2 - 100 mV
DEAD TIME: Adjustable to compensate for dead time of the detector
and electronics (can be read on the display)
OVERLOAD: Senses detector saturation (indicated by display
reading"-OL-")
OVERRANGE: Indicates the radiation field being measured has
exceeded the counting range of the instrument (indicated by display
reading "----")
DATA OUTPUT: 9 pin connector providing 5 decade log output, RS-232
output, signal ground connection, FAIL and Alarm signals (current sink),
and direct connection to battery and ground
REMOTE(optional): Model 271, or Model 272 remote units
POWER: 95 - 135 VAC (178 - 240 VAC available), 50 - 60 Hz
single phase (less than 100 mA), 6 volt sealed lead acid
rechargeable battery (built in)
BATTERY LIFE: Typically 48 hours in non-alarm condition, 12 hours
in alarm condition
BATTERY CHARGER: Battery is continuously trickle charged when
instrument is connected to line power and turned on
CONSTRUCTION: Aluminum housing with ivory polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 7.4" (18.7 cm)H X 9.7" (24.6 cm)W X 2.5" (6.4
cm)L
WEIGHT: 6.5 lbs (2.3 kg)
|
|